SURGE ARRESTER ELTAKO MUA-30 T1+T2+T3,3L+N+PE

Product code
3209101
Combined protection MUA-30 reliably protects electrical systems from transient overvoltages. Combines lightning current and overvoltage protection in a single device. Ideal choice for TN/TT networks with high overvoltage protection requirements. Simple DIN-rail mounting and modular design enable fast installation and maintenance. Combines Type 1, Type 2, and Type 3 overvoltage protection in one device, offering reliable protection against both direct lightning strike effects and building-wide transient overvoltages. MUA-30 is recommended when, for example, the cable length between the main/metering distribution board and the sub-distribution/distribution board exceeds 10 meters. If a building has an external lightning protection system, staged overvoltage protection must be implemented: Type 1 in the main/metering distribution board (e.g., MUA-100, MUA-50). Type 2 in sub-distribution/distribution boards (e.g., MUA-30, MUA-20). Type 2 overvoltage protection in a sub-distribution board is required only if the cable length from the main distribution board equipped with Type 1+2+3 overvoltage protection exceeds 10 meters. TECHNICAL DATA Grounding system TN/TT Rated voltage 230/400V Maximum operating voltage 275V Nominal discharge current 30kA Maximum discharge current 60kA Impulse discharge current 7.5kA/line Protection level 1.5kV Response time ≤ 25ns Overcurrent protective device (max.) 160A gL/gG Short-circuit withstand at maximum overcurrent 25kA Protection class IP20 Conductor terminals 35 mm² 4 modules = width 72 mm Spare module EM/MUA-30 (Serial No. 32 091 06) Overvoltage Protection Selection Guide Main Distribution Board / Metering Board Does the building have an external lightning protection system (class 3 or 4)? - Select MUA50. Does the building have an overhead line supply or is it located in a rural or sparsely populated area? - Select MUA30 or MUA50. Is the building located in a densely populated urban area? - Select MUA20. Sub-distribution Board / Distribution Board Is the incoming supply cable to the sub-distribution board longer than 10 m? - Select MUA20. Is the incoming supply cable to the sub-distribution board shorter than 10 m? - Overvoltage protection is not required. This product description is an automated translation of the original Finnish description.

Product details

Technical specifications

Product class (ETIM)Surge protection device for power supply systems (EC000941)
System configuration DCno
System configuration ITno
System configuration TNyes
System configuration TN-Cyes
System configuration TN-C-Syes
System configuration TN-Syes
System configuration TTyes
System configuration otheryes
Number of conductors (without earthing)4
Nominal discharge surge current (8/20)30 kA
Max. discharge surge current (8/20)60 kA
Nominal voltage AC230 V
Max. continuous voltage AC275 V
Voltage protection level1.5 kV
Max. overcurrent protection device, parallel connection (fuse)160 A

Product codes

SAPDLZ819
STK3209101
PLC3209101
GTIN/EAN4010312502211
Manufacturer part numberMUA-30
Vendor material number3209101

Basic information

Package measurements (L x W x H)94 x 72 x 74 mm
Package volume0.501 l
Package weight0.4 kg
Base uniteach
Package units1
Package contents
UNSPSC39121610
BrandELTAKO
VendorELTAKO GMBH