Roll over image to zoom in
ANTENNA CABLE GROUND 10.0mm 12.7dB/250 AL BLACK Fca
Product code
0232368
AL 117 PE A RG11 cable is designed for outdoor use or as a buried cable and withstands moisture and sunlight well due to its black PE outer sheath. The cable is used in outdoor environments and has a fire classification of Fca. The recommended pulling length for this 10 mm diameter cable is 1-80 meters. If the cable is installed underground, it must be placed in a conduit, as there is no vaseline insulation beneath the PE outer sheath.
Suitable for outdoor installations or buried cables in antenna and multimedia networks, the cable meets the performance requirements of demanding networks. Features of this long-life cable include a pure copper center conductor, triple shielded construction with laminated Al-foils and Al-wire braid, gas-filled inner insulation, low attenuation, high reflection attenuation > 25 dB @ 5-1200 MHz, high shielding attenuation Class A; > 90 dB @ 30-1200 MHz, and characteristic impedance < 4 mOhm/m @ 5-30 MHz.
Connectors: F-compression connector FM-RG11-CX3-QM 10.5, part no. 75 414 19
250 m reel.
Reel size 3000 m.
Technical specifications:
Cable Construction
Center Conductor
Ř 1.63 mm Pure copper
Insulation
Ř 7.15 mm Gas Injected
Skin/Foam/Skin PE
1. Outer Conductor
Aluminum foil
Laminated to insulation
2. Outer Conductor
Aluminum wire braid
55% braid coverage
3. Outer Conductor
Aluminum foil
Laminated to outer insulation
Outer Sheath
Ř 10.00 mm PE
Reel Size / Electrical Number
250 m / 02 323 68
500 m / 02 323 71
Mechanical Properties
Cable weight 78 kg/km
Copper weight 19 kg/km
Minimum bending radius 75 mm
Maximum tensile strength 225 N
Operating temperature -30 °C ... +70 °C
Packaging 250 m
Electrical Properties
Impedance 75 ± 2 ohm
Capacitance 53 ± 2 pF/m
Velocity factor % 84
Insulation resistance > 2 G ohm x km
Operating voltage 2000 V
Test voltage 5000 V
Center conductor DCR < 8.50 ohm/km
Attenuation (20°C)
5 MHz 1.40 dB/100m
50 MHz 3.00 dB/100m
230 MHz 6.40 dB/100m
470 MHz 9.00 dB/100m
862 MHz 12.70 dB/100m
1000 MHz 14.05 dB/100m
1750 MHz 18.75 dB/100m
2150 MHz 21.80 dB/100m
2400 MHz 23.10 dB/100m
3000 MHz 26.80 dB/100m
Reflection Attenuation (20°C)
5-470 MHz > 30 dB
470-1200 MHz > 25 dB
1200-2000 MHz > 23 dB
2000-3000 MHz > 18 dB
Characteristic Impedance
5-30 This product description is an automated translation of the original Finnish description.
Suitable for outdoor installations or buried cables in antenna and multimedia networks, the cable meets the performance requirements of demanding networks. Features of this long-life cable include a pure copper center conductor, triple shielded construction with laminated Al-foils and Al-wire braid, gas-filled inner insulation, low attenuation, high reflection attenuation > 25 dB @ 5-1200 MHz, high shielding attenuation Class A; > 90 dB @ 30-1200 MHz, and characteristic impedance < 4 mOhm/m @ 5-30 MHz.
Connectors: F-compression connector FM-RG11-CX3-QM 10.5, part no. 75 414 19
250 m reel.
Reel size 3000 m.
Technical specifications:
Cable Construction
Center Conductor
Ř 1.63 mm Pure copper
Insulation
Ř 7.15 mm Gas Injected
Skin/Foam/Skin PE
1. Outer Conductor
Aluminum foil
Laminated to insulation
2. Outer Conductor
Aluminum wire braid
55% braid coverage
3. Outer Conductor
Aluminum foil
Laminated to outer insulation
Outer Sheath
Ř 10.00 mm PE
Reel Size / Electrical Number
250 m / 02 323 68
500 m / 02 323 71
Mechanical Properties
Cable weight 78 kg/km
Copper weight 19 kg/km
Minimum bending radius 75 mm
Maximum tensile strength 225 N
Operating temperature -30 °C ... +70 °C
Packaging 250 m
Electrical Properties
Impedance 75 ± 2 ohm
Capacitance 53 ± 2 pF/m
Velocity factor % 84
Insulation resistance > 2 G ohm x km
Operating voltage 2000 V
Test voltage 5000 V
Center conductor DCR < 8.50 ohm/km
Attenuation (20°C)
5 MHz 1.40 dB/100m
50 MHz 3.00 dB/100m
230 MHz 6.40 dB/100m
470 MHz 9.00 dB/100m
862 MHz 12.70 dB/100m
1000 MHz 14.05 dB/100m
1750 MHz 18.75 dB/100m
2150 MHz 21.80 dB/100m
2400 MHz 23.10 dB/100m
3000 MHz 26.80 dB/100m
Reflection Attenuation (20°C)
5-470 MHz > 30 dB
470-1200 MHz > 25 dB
1200-2000 MHz > 23 dB
2000-3000 MHz > 18 dB
Characteristic Impedance
5-30 This product description is an automated translation of the original Finnish description.
Product details
Technical specifications
Product class (ETIM)Coaxial cable (EC000019)
Paired co-axial cableno
2 core co-axial cable (twinax)no
Diameter inner conductor1.63 mm
Inner conductor materialCopper
Inner conductor surfaceBare
Inner conductor categoryClass 1 = solid
Diameter outer conductor7.15 mm
Outer conductor materialAluminium
Outer conductor surfaceBare
Type of outer conductorFoil + braiding
DielectricPolyethylene, foamed (foam PE)
Number of screen layers3
Armouring/reinforcementNone
Material armouringOther
With rodent protectionno
Product codes
SAPCGX566
STK0232368
PLC0232368
GTIN/EAN6410002323689
Manufacturer part numberAL117 PE A/HQ 163
Vendor material number0232368
Basic information
Package measurements (L x W x H)1000 x 10 x 10 mm
Package volume0.166 l
Package weight0.07 kg
Base unitMeter
Package units250 / 3000
Package contents–
UNSPSC26121507
BrandLAATUANTENNI
VendorLAATUANTENNI OY
Documents (6)
Certificates
Brochures & documents
Links