CROSS CONNECTOR 256/A DIN
Product code
5808086
Connector 256 A-DIN 30 FT 2x30mm for flat surface
The grounding system is part of the external lightning protection that conducts the lightning current to the ground and distributes it there. The most important criteria for the even distribution of the lightning current without the formation of dangerous overvoltages are the shape and dimensions of the grounding electrode. Standard EN 62305-3 (IEC 62305-3) recommends as low a grounding resistance as possible < 10 ohms. The grounding system can be constructed using one of the following three systems. It is possible to connect different grounding systems together, but potential corrosion risks must be taken into account. Important guideline: Grounding systems must be connected to the potential equalization system!
When a direct lightning strike hits a building protected by external lightning protection, large potential differences can arise between the building and installed systems (electrical, telecommunications cables), leading to dangerous fires and damage. Nearby lightning strikes generate strong magnetic fields that can damage electrical equipment. But even lightning strikes at a distance of up to 2 km can generate dangerous overvoltages in the building's electrical equipment. OBO provides all necessary products for implementing reliable lightning protection: lightning rods, surge protectors, potential equalization and grounding accessories. This product description is an automated translation of the original Finnish description.
The grounding system is part of the external lightning protection that conducts the lightning current to the ground and distributes it there. The most important criteria for the even distribution of the lightning current without the formation of dangerous overvoltages are the shape and dimensions of the grounding electrode. Standard EN 62305-3 (IEC 62305-3) recommends as low a grounding resistance as possible < 10 ohms. The grounding system can be constructed using one of the following three systems. It is possible to connect different grounding systems together, but potential corrosion risks must be taken into account. Important guideline: Grounding systems must be connected to the potential equalization system!
When a direct lightning strike hits a building protected by external lightning protection, large potential differences can arise between the building and installed systems (electrical, telecommunications cables), leading to dangerous fires and damage. Nearby lightning strikes generate strong magnetic fields that can damage electrical equipment. But even lightning strikes at a distance of up to 2 km can generate dangerous overvoltages in the building's electrical equipment. OBO provides all necessary products for implementing reliable lightning protection: lightning rods, surge protectors, potential equalization and grounding accessories. This product description is an automated translation of the original Finnish description.
Product details
Technical specifications
Product class (ETIM)Connector for lightning protection (EC000514)
Type of connectionCross connector
Diameter round conductor 10 - 0 mm
Width flat conductor 130 - 30 mm
Diameter round conductor 20 - 0 mm
Width flat conductor 230 - 30 mm
MaterialSteel
Surface protectionHot-dip galvanised
Type of fastening screwsHexagon screw
Lightning current load-bearing capacity (10/350 µs)100 kA
Product codes
SAPACR456
STK5808086
PLC5808086
GTIN/EAN4012195419471
Manufacturer part number5314658
Vendor material number5314658
Basic information
Package measurements (L x W x H)200 x 150 x 100 mm
Package volume3 l
Package weight0.226 kg
Base uniteach
Package units1 / 10
Package contents–
UNSPSC39131705
BrandOBO BETTERMANN
VendorOBO BETTERMANN OY
The country of origin stated by the supplierFinland