MOTOR CIRCUIT-BREAKER TESYS 70-150A 55-75kW 400V 70KA
Product code
3781749
Reliable and robust motor protection circuit breakers up to 500A/250kW/400V with a wide-range protective relay.
TeSys GV5 and GV6 motor protection circuit breakers are designed to protect motors against overload, short-circuit, phase imbalance, and phase loss.
The breakers are specifically designed for demanding motor control and protection applications.
? 4 rated currents: 150A, 220A, 320A & 500A
? 2 short-circuit withstand ratings (Icu): 36kA & 70kA @ 400/415V AC
? Ics = 100% Icu
? Equipped with a Micrologic protective relay designed to protect the motor against overload and short-circuit conditions and to act as phase imbalance and phase loss protection.
? Adjustable overload protection setting range (Ir): 50...100% x In and starting time class setting (Class 5, 10 or 20)
? Adjustable short-circuit trip setting range (Isd): 5...13 x In with fixed time delay
? Instantaneous short-circuit trip (Ii): 15 x In (maximum relay current)
? Relay LED indication. Green LED: operational status (ready to trip). Red LED: predictive alarm signal, motor thermal state >95% of rated value
? Manual operation as standard
? Handle operation as optional accessory
? Wide range of electrical accessories and mechanical fittings
? Cable lug/bar connection as standard. Tunnel connectors optional.
? Standards: EN/IEC 60947-1; IEC 60947-2; IEC 60947-4-1; UL 60947-4-1; CSA C22.2 No 60947-4-1
? Optional fault discrimination module (SDTAM) enabling detection of overload and triggering contactor opening (before tripping) in overload and phase imbalance conditions
? Type 1 and Type 2 short-circuit coordination for two-component motor starter solutions together with TeSys contactors This product description is an automated translation of the original Finnish description.
Product details
Technical specifications
Product class (ETIM)Motor protection circuit-breaker (EC000074)
Overload release current setting70-150 A
Adjustment range undelayed short-circuit release150-150 A
With thermal overload protectionyes
Phase failure sensitiveyes
Switch off techniqueThermomagnetic
Rated operating voltage0-690 V
Rated permanent current Iu150 A
Rated operation power at AC-3, 230 V75 kW
Rated operation power at AC-3, 400 V110 kW
Power loss27.6 W
Type of electrical connection of main circuitScrew connection
Type of control elementTurn button
Device constructionComplete device in housing
With integrated auxiliary switchno
With integrated under voltage releaseno
Product codes
SAPCHT889
STK3781749
PLC3781749
GTIN/EAN3606489915414
Manufacturer part numberGV5P150H
Vendor material number3781749
Basic information
Package measurements (L x W x H)181 x 112 x 181 mm
Package volume3.669 l
Package weight2.192 kg
Base uniteach
Package units1 / 6
Package contents–
UNSPSC39121521
BrandSCHNEIDER ELECTRIC
VendorSCHNEIDER ELECTRIC FINLAND OY
Documents (6)
Images
Brochures & documents
Links
Environment and safety
Carbon footprint data
Carbon footprint of product manufacturing (A1–A3 GWP value)40.0412
GWP, uniteach
Source for GWP dataEPD
Documents (1)
Sustainability brochures & documents
Manufacturer
NameSchneider Electric Finland Oy
Websitehttps://www.se.com/fi/fi/
Postal addressSokerilinnantie 11 C, 02600 Espoo, Finland