JORDFEILAUTOMAT ACTI9 IC60 RCBO 4P 10A 30MA C 6kA A

Product code
3254324
Acti 9 iC60 RCBO (2P, 3P, 4P) - residual current circuit breakers
Acti 9, designed for low-voltage DIN rail systems, enhances safety and operational continuity thanks to its unique features.
  • VisiSafe: ensures safe operation and maintenance of circuits. Class 2 insulation guarantees the safety of users and untrained personnel.
  • VISI-TRIP: quickly detects faulty miniature circuit breakers and accelerates fault resolution.
  • Completely immune post-installation residual current devices (RCD): improved operational continuity, especially in dirty environments and networks.
  • Reflex iC60 all-in-one concept: one device integrates a circuit breaker, contactor, and pulse relay.
  • Schneider Electric guarantees perfect compatibility.
  • Optimized design time especially for lighting systems in residential buildings.
  • 50% fewer connections with the Reflex iC60 all-in-one concept.
  • Adaptable, upgradable solutions and easy operation.
  • Easier status diagnosis via indicator lights on the front panel.
  • Multiclip distribution systems are suitable for electrical system upgrades, additional device installations, phase balancing, etc.
  • Easily adaptable to constraints and last-minute changes in commercial, office, and industrial buildings.
  • Choice of operation and monitoring mode.
  • Interface to building management systems
  • Costs associated with accessing remote buildings can be reduced through new automatic remote control.
Benefits

  • Acti 9 is a DIN rail-mounted switching system that combines your own safety with the safety of your customers and their installations.
  • Acti 9 is packed with innovations.
  • Acti 9 reflects the advantages of Schneider Electric’s over 40 years of experience.
  • Acti 9 covers all applications, especially in dirty environments and networks, ensuring absolute safety and operational continuity. Example: VisiTrip detects faulty outputs.
  • Acti 9 is easy to install and environmentally friendly. Example: Its components are 100% recyclable.
Applications
  • Low-voltage final distribution
  • Protection with miniature circuit breakers (MCB) in all commercial and industrial buildings.
  • Protection of motor circuits. Protection of DC circuits.
  • Protection of people and property with super-immune residual current devices (RCD).
  • Protection against overvoltages from atmospheric sources using surge protection devices.
  • Monitoring of power and control circuits using contactors and pulse relays.
  • Remote control of circuits via integrated remote control devices connected to miniature circuit breakers (MCB). Remote control and protection via integrated circuit breakers.
  • Programming, setting, signaling, etc.
This product description is an automated translation of the original Finnish description.

Product details

Technical specifications

Product class (ETIM)Earth leakage circuit breaker (EC000905)
Number of poles (total)4
Number of protected poles4
Rated voltage400 V
Rated insulation voltage Ui500 V
Rated impulse withstand voltage Uimp4 kV
Rated current10 A
Rated fault current0.03 A
Mounting methodDIN rail
Leakage current typeA
Current limiting class1
Power loss3.2 W
Rated short-circuit breaking capacity according to EN 610096 kA
Rated short-circuit breaking capacity according to IEC 60947-26 kA
Rated short-circuit breaking capacity Icn according to EN 61009-16 kA
Disconnection characteristicUndelayed

Product codes

SAPCDT837
STK3254324
PLC3254324
GTIN/EAN3606481157591
Manufacturer part numberA9D67410
Vendor material number3254324

Basic information

Package measurements (L x W x H)100 x 80 x 87 mm
Package volume0.696 l
Package weight0.42 kg
Base uniteach
Package units1 / 18
Package contents
UNSPSC39121614
BrandSCHNEIDER ELECTRIC
VendorSCHNEIDER ELECTRIC FINLAND OY

Documents (2)

Brochures & documents