Roll over image to zoom in


RCCB IID 4P 25A 30MA A
Product code
3254107
Acti 9 iID residual current circuit breakers (RCCB), designed for installation on DIN rails, work together with iC60 circuit breakers (MCB, Miniature Circuit Breaker) to protect people and equipment against electric shocks and fires.
Why choose Acti 9?
- VISI-SAFE: Clear indication of the breaker's status for safe operation and maintenance.
- Class 2 isolation: Ensures safety for users and untrained personnel from the rear.
- VisiTrip: Quickly identify a faulty protective breaker and accelerate resolution of the issue.
- SI-type immune residual current devices: Enhanced operational continuity in environments and networks subject to electrical or climatic disturbances.
- Optional electrical and mounting accessories are identical to those for Acti 9 iC60 miniature circuit breakers (MCB).
- Rated current: 1 ... 100 A
- Si (Super immune), AC, A
- Sensitivity 30 mA: Additional protection against fire and indirect contact (in accordance with IEC 60364 standard)
- Sensitivities 100 mA, 300 mA, 500 mA: Additional protection against fire and indirect contact (in accordance with IEC 60364 standard)
- Selective version: Ensures proper discrimination between different residual current circuit breakers (RCCB) and the device closest to the fault.
- Full coordination with Acti 9 and Multi 9 miniature circuit breakers (MCB)
- Compliant with IEC 61008-1 standard and certified by local authorities
- Compatible with IEC/EN 60947-2 standard for isolation
- Operating voltage: up to 400 VAC, isolation voltage: 500 V
- Optional accessories: status and trip indication, shunt trip, undervoltage trip, overvoltage trip
Why choose Acti 9?
- Easier selection thanks to clear part numbers
- Easier installation due to robust terminals
- Environmental friendliness thanks to 100% recyclable materials
Product details
Technical specifications
Product class (ETIM)Residual current circuit breaker (RCCB) (EC000003)
Number of poles4
Rated voltage400 V
Rated current25 A
Rated fault current30 A
Rated insulation voltage Ui500 V
Rated impulse withstand voltage Uimp6 kV
Power loss3.2 W
Mounting methodDIN rail
Leakage current typeA
Selective protectionno
Short-time delayed trippingno
Short-circuit breaking capacity (Icw)10 kA
Surge current capacity0.25 kA
Voltage typeAC
With interlocking deviceyes
Product codes
SAPGDM332
STK3254107
PLC3254107
GTIN/EAN3606480443176
Manufacturer part numberA9Z21425
Vendor material number3254107
Basic information
Package measurements (L x W x H)101 x 77 x 84 mm
Package volume0.653 l
Package weight0.378 kg
Base uniteach
Package units1 / 27
Package contents1
UNSPSC39121614
BrandSCHNEIDER ELECTRIC
VendorSCHNEIDER ELECTRIC FINLAND OY
Documents (5)
Brochures & documents
Links
Environment and safety
Carbon footprint data
Carbon footprint of product manufacturing (A1–A3 GWP value)1.1779
GWP, uniteach
Source for GWP dataEPD
Documents (1)
Sustainability brochures & documents