Earth leakage circuit breaker iDPN H Vigi, 1p+N, 16A, 30mA class SI
Acti 9 iDPN N Vigi Residual Current Circuit Breakers
Protection for single-phase groups
iDPN Vigi
iDPN Vigi is a combined 1-pole circuit breaker and residual current device with a width of 2 modules (36 mm). The protection is electromechanical and operates without an external power supply.
The same electrical accessories used in the iC60 series can be used with iDPN Vigi breakers. Busbar product numbers: 21505, 21507, and 21093
Technical specifications:
Rated voltage: 230V AC
Rated current: iDPN N Vigi 4 - 40A, iDPN H Vigi 6 - 32A, B- and C-characteristic
Rated residual operating current: iDPN N Vigi 30, 100, and 300 mA, iDPN H Vigi 30 and 300 mA
Breaking capacity: iDPN N Vigi 6kA, iDPN H Vigi 10kA
Connections: tunnel terminals for cables up to 10mm² This product description is an automated translation of the original Finnish description.
Protection for single-phase groups
iDPN Vigi
iDPN Vigi is a combined 1-pole circuit breaker and residual current device with a width of 2 modules (36 mm). The protection is electromechanical and operates without an external power supply.
The same electrical accessories used in the iC60 series can be used with iDPN Vigi breakers. Busbar product numbers: 21505, 21507, and 21093
Technical specifications:
Rated voltage: 230V AC
Rated current: iDPN N Vigi 4 - 40A, iDPN H Vigi 6 - 32A, B- and C-characteristic
Rated residual operating current: iDPN N Vigi 30, 100, and 300 mA, iDPN H Vigi 30 and 300 mA
Breaking capacity: iDPN N Vigi 6kA, iDPN H Vigi 10kA
Connections: tunnel terminals for cables up to 10mm² This product description is an automated translation of the original Finnish description.
Product details
Technical specifications
Product class (ETIM)Earth leakage circuit breaker (EC000905)
Number of poles (total)2
Number of protected poles1
Rated voltage230 V
Rated insulation voltage Ui400 V
Rated impulse withstand voltage Uimp4 kV
Rated current16 A
Rated fault current0.03 A
Mounting methodDIN rail
Leakage current typeA
Current limiting class3
Power loss4.3 W
Rated short-circuit breaking capacity according to EN 6100910 kA
Rated short-circuit breaking capacity Icn according to EN 61009-110 kA
Disconnection characteristicUndelayed
Surge current capacity3 kA
Product codes
SAPCAL022
STK3257616
PLC3257616
GTIN/EAN3606480484421
Manufacturer part numberA9D38616
Vendor material number3257616
Basic information
Package measurements (L x W x H)100 x 85 x 40 mm
Package volume0.34 l
Package weight0.213 kg
Base uniteach
Package units1 / 54
Package contents–
UNSPSC39121614
BrandSCHNEIDER ELECTRIC
VendorSCHNEIDER ELECTRIC FINLAND OY
Documents (3)
Brochures & documents
Links
Environment and safety
Manufacturer
NameSchneider Electric Finland Oy
Websitehttps://www.se.com/fi/fi/
Postal addressSokerilinnantie 11 C, 02600 Espoo, Finland