Roll over image to zoom in
RESIDUAL CURRENT DEVICE, RCBO IDPN 2X6A/C/30MA/SI/10KA
Product code
3257606
Earth leakage circuit breaker iDPN H Vigi, 1p+N, 6A, 30mA class SI
Acti 9 iDPN N Vigi Residual Current Circuit Breakers
Protection for single-phase groups
iDPN Vigi
iDPN Vigi is a combined 1-pole circuit breaker and residual current device with a width of 2 modules (36 mm). The protection is electromechanical and operates without an external power supply.
The same electrical accessories used in the iC60 series can be used with iDPN Vigi breakers. Busbar product numbers: 21505, 21507, and 21093
Technical specifications:
Rated voltage: 230V AC
Rated current: iDPN N Vigi 4 - 40A, iDPN H Vigi 6 - 32A, B- and C-characteristic
Rated residual operating current: iDPN N Vigi 30, 100, and 300 mA, iDPN H Vigi 30 and 300 mA
Breaking capacity: iDPN N Vigi 6kA, iDPN H Vigi 10kA
Connections: tunnel terminals for cables up to 10mm² This product description is an automated translation of the original Finnish description.
Protection for single-phase groups
iDPN Vigi
iDPN Vigi is a combined 1-pole circuit breaker and residual current device with a width of 2 modules (36 mm). The protection is electromechanical and operates without an external power supply.
The same electrical accessories used in the iC60 series can be used with iDPN Vigi breakers. Busbar product numbers: 21505, 21507, and 21093
Technical specifications:
Rated voltage: 230V AC
Rated current: iDPN N Vigi 4 - 40A, iDPN H Vigi 6 - 32A, B- and C-characteristic
Rated residual operating current: iDPN N Vigi 30, 100, and 300 mA, iDPN H Vigi 30 and 300 mA
Breaking capacity: iDPN N Vigi 6kA, iDPN H Vigi 10kA
Connections: tunnel terminals for cables up to 10mm² This product description is an automated translation of the original Finnish description.
Product details
Technical specifications
Product class (ETIM)Earth leakage circuit breaker (EC000905)
Number of poles (total)2
Number of protected poles1
Rated voltage230 V
Rated insulation voltage Ui400 V
Rated impulse withstand voltage Uimp4 kV
Rated current6 A
Rated fault current0.03 A
Mounting methodDIN rail
Leakage current typeA
Current limiting class3
Power loss3 W
Rated short-circuit breaking capacity according to EN 6100910 kA
Rated short-circuit breaking capacity Icn according to EN 61009-110 kA
Disconnection characteristicOther
Surge current capacity3 kA
Product codes
SAPCAL068
STK3257606
PLC3257606
GTIN/EAN3606480484407
Manufacturer part numberA9D38606
Vendor material number3257606
Basic information
Package measurements (L x W x H)100 x 80 x 40 mm
Package volume0.32 l
Package weight0.213 kg
Base uniteach
Package units6 / 54 / 432
Package contents–
UNSPSC39121614
BrandSCHNEIDER ELECTRIC
VendorSCHNEIDER ELECTRIC FINLAND OY
Documents (4)
Brochures & documents
Links
Environment and safety
Carbon footprint data
Carbon footprint of product manufacturing (A1–A3 GWP value)0.2103
GWP, uniteach
Source for GWP dataEPD
Documents (1)
Sustainability brochures & documents
Manufacturer
NameSchneider Electric Finland Oy
Websitehttps://www.se.com/fi/fi/
Postal addressSokerilinnantie 11 C, 02600 Espoo, Finland