Roll over image to zoom in






SURGE ARRESTER ELTAKO MUA-50 T1+T2+T3,3L+N+PE,12,5KA
Product code
3209102
Combined protection device MUA-50 reliably protects electrical systems from transient overvoltages.
It provides high-level protection against direct lightning strikes in TT, TN-C, and TN-S systems.
Discharge current capacity: 12.5 kA per pole.
Simple DIN-rail mounting and modular design enable quick installation and maintenance.
Integrates Type 1, Type 2, and Type 3 surge protection into a single device, enabling comprehensive protection from the building's electrical connection all the way to the end equipment.
The MUA-50 combined surge protector is recommended for new constructions and renovation projects featuring high-power electrical equipment (e.g., electric vehicle charging stations, air-source heat pumps, photovoltaic systems).
If a building has an external lightning protection system, staged surge protection must be implemented:
Type 1 at the main/distribution metering center (e.g., MUA-100, MUA-50).
Type 2 at group/distribution boards (e.g., MUA-30, MUA-20).
Type 2 surge protection at sub-distribution boards is required only if the cable length from the main board (equipped with Type 1+2+3 surge protection) exceeds 10 meters.
TECHNICAL DATA
Rated voltage AC (50/60 Hz): 240 V
Maximum continuous operating voltage (AC) (L1-N)(N-PE): 300 V / 305 V
Nominal discharge current (8/20 μs) (L-N)(N-PE): 20 kA / 80 kA
Maximum discharge current (8/20 μs) (L-N)(N-PE): 50 kA / 100 kA
Impulse discharge current (10/350 μs) (L-N)(N-PE): 12.5 kA / 50 kA
Specific energy (L-N)(N-PE): 39 kJ/Ω / 225 kJ/Ω
Charge capacity (L-N)(N-PE): 3.75 As / 15 As
Combined protector open-circuit voltage: 6 kV
Combined protector open-circuit voltage (L-N)(N-PE): 1500 V / 1500 V
AC RMS current: 100 ARMS
Response time (L-N)(N-PE): < 100 ns / < 100 ns
Overcurrent protective device (max.): 160 AgG
Short-circuit current rating (AC): 25 kA
TOV withstand capability: 120 minutes at 442 V
TOV withstand capability: 200 minutes at 1200 V
According to EN 61643-11: Type 1+2+3
4 modules = width 72 mm
Replacement module EM/MUA-50MOD (Serial No. 32 091 07)
Replacement module EM/MUA-50GTD (Serial No. 32 091 08) (yellow)
Surge Protector Selection Guide
Main Board / Metering Board
Does the building have an external lightning protection system (Class 3 or 4)?
- Select MUA50.
Does the building have an overhead supply line or is it located in a rural or sparsely populated area?
- Select MUA30 or MUA50.
Is the building located in a densely populated urban area?
- Select MUA20.
Group Board / Distribution Board
Is the supply cable to the sub-distribution board longer than 10 m?
- Select MUA20.
Is the supply cable to the sub-distribution board shorter than 10 m?
- No surge protection is required. This product description is an automated translation of the original Finnish description.
Product details
Technical specifications
Product class (ETIM)Surge protection device for power supply systems (EC000941)
System configuration DCno
System configuration ITno
System configuration TNyes
System configuration TN-Cyes
System configuration TN-C-Syes
System configuration TN-Syes
System configuration TTyes
System configuration otheryes
Number of conductors (without earthing)4
Nominal discharge surge current (8/20)20 kA
Max. discharge surge current (8/20)50 kA
Nominal voltage AC240 V
Max. continuous voltage AC300 V
Voltage protection level1.5 kV
Voltage protection level L-N1.5 kV
Product codes
SAPDLZ820
STK3209102
PLC3209102
GTIN/EAN4010312502204
Manufacturer part numberMUA-50
Vendor material number3209102
Basic information
Package measurements (L x W x H)94 x 84 x 74 mm
Package volume0.584 l
Package weight0.46 kg
Base uniteach
Package units1
Package contents–
UNSPSC39121610
BrandELTAKO
VendorELTAKO GMBH
Documents (8)
Brochures & documents
Links