CABLE CABINET E-MOBILITY AHMA LK16608X
- Rated current 160A (selectable 100A / 125A / 160A)
- Outputs: 8x MCN363E (Hager circuit breaker C-curve 63A, 3-pole)
- Supply: Compact breaker HHT160DR with mounting rail (Hager H3+)
- Network analyzer with ModBus communication (Circutor CVM-C11)
- Supply connectors HYT005H (Al/Cu 50-185mm²)
- Charging outputs: Al/Cu terminal connectors 2.5-35mm²
In electric vehicle charging, the output components of the station often operate near their rated current, making temperature management critically important for the station’s service life.
The station incorporates temperature management requirements according to charging load:- Field-specific ventilation
- Air gaps in charging outputs
- Thermal emergency shutdown function
Charging output balancing factor 1 (as required by the charging station standard).
The station features DIN-rail mounting for sensors, enabling readiness for dynamic temperature management. When connected to an eParking backend system, the charging station can dynamically control charging load based on the temperature of output components.
Service Life ManagementThe station includes a dedicated device space for load management devices. This device space is a general-purpose area suitable for installing any device. The space reserves capacity for an eTolppa system load management device (eG) to support multi-level load management. When the eTolppa load management device is installed in the station, no separate connection device is required at charging points.
If the thermal emergency shutdown function repeatedly interrupts power supply during the station’s service life, it is advisable to implement dynamic temperature management. In this mode, the backend system can continuously limit charging station loads based on the temperature of output components.
The station includes reserved space for a harmonic filter. The network analyzer can monitor the development of harmonic distortions, and a harmonic filter can be easily added later. Alarms related to this can be configured on the analyzer.
The station also includes a separate space for spare outputs. The spare output space is standardly equipped with 3x C10 and 2x C16 (1-pole) circuit breakers (for additional electrical needs). Spare outputs are not wired to busbars.
This product description is an automated translation of the original Finnish description.